# FastGene NanoSpec Spectrophotometer

---
url: https://www.nippongenetics.eu/en/products/lab-instruments/photometer/fastgene-nanospec-photometer/
language: en
type: product
modified: 2026-04-27T09:21:03+02:00
---

## All-round microvolume spectrophotometer

## Product Details

- **SKU**: FG-NP01
- **Stock status**: instock
- **Categories**: Lab Instruments, Photometer

Microvolume drop and cuvette reader | High end quantitative DNA/RNA and protein analysis (full spectrum: 190-850 nm) | Stand-alone device with integrated control unit | Simple and intuitive menu | 20 pre-configurated measuring modes

- **Best device performance:** Microvolume drop and cuvette reader
- **Powerful:** high end quantitative DNA/RNA and protein analysis (full spectrum: 190-850 nm)
- **Cost-saving**: stand-alone device with integrated control unit
- **Convenient usage**: simple and intuitive menu
- **Highest reliability:** 20 pre-configurated measuring modes

[PRODUCT INQUIRY](#section-inquiry_form)

### Details

##### All-round UV-VIS microvolume spectrophotometer

![NanoSpec Photometer in the lab](https://www.nippongenetics.eu/app/uploads/2020/12/NanoSpec-labview-01.png)

The FastGene® NanoSpec Photometer is a compact **microvolume UV-Vis spectrophotometer** characterised by highest **user-friendliness**.
It enables fast and easy quantification and analysis of nucleic acids and proteins by UV-Vis absorption spectrophotometry.
Integrating a **microvolume sample measuring mode** and a **cuvette measuring mode,** the measurement of a wide concentration range is enabled.
You can easily set over 20 measuring modes.

##### **![](https://www.nippongenetics.eu/app/uploads/2020/12/stars-best-device.png)**

##### Best device performance

and versatile quantitative analysis (e.g., dsDNA, ssDNA, RNA, lysozyme, BSA, OD600) due to full spectrum analysis (190 nm–850 nm)##### **![](https://www.nippongenetics.eu/app/uploads/2020/12/versatile-use-icon2.png)**

##### Extended use

for protein measurement and cell counting due to the cuvette mode##### **![](https://www.nippongenetics.eu/app/uploads/2020/12/sample-saving-icon2.png)**

##### Sample-saving

due to microvolume mode (1–2 µL sample volume)##### **![](https://www.nippongenetics.eu/app/uploads/2020/12/touchscreen-icon.png)**

##### Convenient utility

due to an intuitive menu and user-specific workspace after individual login##### **![](https://www.nippongenetics.eu/app/uploads/2020/12/clean-surface-icon2.png)**

##### Clean workplace

due to glove-compatible LCD touch-screen**![](https://www.nippongenetics.eu/app/uploads/2020/12/approved-icon.png)**##### Highest reliability

in results due to 20 pre-configurated measuring modes ensuring secure utilization**![](https://www.nippongenetics.eu/app/uploads/2020/12/money-saving-icon3.png)**##### Cost-saving

due to integrated control unit and extensive application options**![](https://www.nippongenetics.eu/app/uploads/2020/12/flexible-usage-icon.png)**##### Flexible usability

e.g., in training laboratories, due to a small footprint of about DINA4-size (21,6 cm x 29 cm) and light weight (3.0 kg)**![](https://www.nippongenetics.eu/app/uploads/2020/12/secure-data-icon2.png)**##### Comfortable and safe data management

due to alternative saving at the device and transfer via USB flash drive**![](https://www.nippongenetics.eu/app/uploads/2020/12/time-saving-icon.png)**##### Reduced application time

due to short measurement times (&lt;8 sec), a series-measurement function, and no need for a lamp warming-up##### Full spectral analysis

The FastGene® NanoSpec measures the absorption spectrum UV-VIS (190 nm–850 nm) in seconds using by array type spectrophotometer technology with Xenon lamp and CMOS sensor (2048 pixels).

##### Measurement modes and configuration

The designated factor of each of the 20 pre-configurated measurement modes is set as the default value, so that no adjustment is needed.

- **Nucleic acids:** dsDNA | ssDNA | RNA | miRNA | Customize\*
- **Protein UV:** BSA | SA | IgB | IgE Human | Lysozyme | OD1 | Mol. Ect. Coeff. | Ext. Coeff.
- **Protein assay:** Bradford | Biuret Assay | BCA Assay | Lowry Assay
- **More:** Kintetics | OD600 | Photometric | Spectrum | ABS Ratio | Concentration | Quantification

\*The input mode (‘Customize’) is provided to allow the users to set a factor value which is different from the default to enable maximal flexibility and specificity.

##### Software and menu navigation

![NanoSpec Photometer - menu](https://www.nippongenetics.eu/app/uploads/2020/12/fg-np01-nanospec-menu.png)

The menu navigation of the FastGene_®_ NanoSpec is very simple and intuitive. The &gt;20 preconfigurated measuring modes can directly be selected.

The input mode (‘Customize’) is provided to allow the users to set a factor value which is different from the default.

Nucleic acid tab:

#### _**![](https://www.nippongenetics.eu/app/uploads/2020/12/fg-np01-main-screen2-300x185.png)**_

Protein UV tab:

![](https://www.nippongenetics.eu/app/uploads/2020/12/fg-np01-protein-uv-mode-configuration.png)

Protein assay tab:

**![](https://www.nippongenetics.eu/app/uploads/2020/12/FG-NP01-protein-assay-mode-configuration.png)**

More applications tab:

![](https://www.nippongenetics.eu/app/uploads/2020/12/fg-np01-more-mode-configuration.png)

##### Statement

_“The FastGene® NanoSpec Photometer is characterized by its simple and intuitive operation system. The desired measurement protocol can be found quickly using the touchscreen and the good menu navigation. The Droplet has an automatic mode, which means that many samples can be measured very quickly without having to make settings again.”_

**Dr. Manuel Franke**
Head of Research and Development
NIPPON Genetics EUROPE

### Videos

##### Introduction video

FastGene® NanoSpec and FastGene® NanoView Photometers | 03:04 min

 Um das YouTube-Video zu sehen, müssen Sie Cookies akzeptieren.

  Cookie-Einstellungen







 ![NanoSpec and NanoView product video](https://www.nippongenetics.eu/app/uploads/2021/06/nanospec-nanoview-video-1024x431.png) ![]()



##### Watch how easy it is to measure DNA concentrations!

03:07 min

 Um das YouTube-Video zu sehen, müssen Sie Cookies akzeptieren.

  Cookie-Einstellungen







 ![](https://www.nippongenetics.eu/app/uploads/video-how-to-measure-dna-with-nanospec-photometer-1024x576.jpg) ![]()



### Specifications

##### ![NanoSpec Photometer - topview](https://www.nippongenetics.eu/app/uploads/2020/12/nanospec-topview.png)

##### Specification

##### FastGene® NanoSpec Photometer

**General specifications**Photometric systemMicrovolume spectrophotometerFootprint (W \* D)216 mm x 290 mmWeight3.0 kg**Optical specifications**DetectorCMOS linear image sensor (2048 pixels)Light SourceXenon flash lampLifetime~ 10 yearsWavelength range190 – 850 nmMeasurement time&lt; 8 secondsSpectral bandwidth1.5 nm (FWHM at Hg 253.7 nm)Wavelength display (setting)1 nmWavelength accuracy± 1 nmAbsorbance precision0.002 AU (0.5 mm path) or 1 %Absorbance accuracy3% (at 0.97A at 302 nm)**Processing / Power / Software**Software compatibilityWindows® 10 and 11CPUOcta Core ARM® CortexTM-A53 ProcessorStorage32 GB internal storageConnectivity4 x USB-A ports, Ethernet, RS232Operating systm (OS)Android**Display**Display7-inch, 1280 x 800 HD color displayTouchscreenMultipoint capacitive touchGlove compatibilityCompatible with lab gloves**Microvolume performance**Minimum sample volume1 µLAbsorbance range0.04 – 330 A (10 mm equivalent)Detection limit (microvolume)- 2 ng/μL (dsDNA)
- 1.6 ng/µL (RNA)
- 0.06 mg/mL (BSA)
- 0.03 mg/mL (IgG human)

Maximum concentration- 16500 ng/μL (dsDNA)
- 13200 ng/µL (RNA)
- 495 mg/mL (BSA)
- 244.2 mg/mL (IgG human)

Pathlength0.05 – 0.7 mm**Cuvette performance**Photometric range0.004 – 2 ADetection limit- 0.2 ng/μL (dsDNA)
- 0.16 ng/µL (RNA)
- 0.006 mg/mL (BSA)
- 0.003 mg/mL (IgG)

Maximum concentration- 100 ng/µL (dsDNA)
- 80 ng/µL (RNA)
- 3.00 mg/mL (BSA)
- 1.48 (IgG)

Center height8.5 mm**Additional accessories**Thermal printer for FastGene® PhotometerCat. No. YJ-360T(S) | 1 printer and 1 roll paper | Please [contact us](https://www.nippongenetics.eu/en/contact/) for more information.Thermal roll paperCat. No. CSM0026 | Pack of 20 rolls | Please [contact us](https://www.nippongenetics.eu/en/contact/) for more information.### FAQ

##### Does the photometer show a warning on the display if the measured sample has an extreme concentration that is above the limit value?

There is no warning regarding the maximum value, but the system displays the maximum saturated value.

##### What about the solvent compatibility of the NanoSpec photometer? Will chlorophyll extracts in acetone and chloroform damage the sample compartment when using the base?

Organic solvents such as acetone and chloroform are highly volatile and cannot be loaded on the pedestal, so experiments cannot be performed using the pedestal. In addition, if the solvent falls on or gets onto the black rubber around the pedestal, it may damage the rubber. The solvent that can be used with the pedestal is an aqueous solution. Organic solvents are difficult to use. It is recommend to use the cuvette mode for measuring these samples.

### Downloads &amp; Service

##### Service for customers

##### [REgister your instrument](https://www.nippongenetics.eu/en/instrument-registration/)

###### Activate our exclusive service now &amp; enjoy your benefits

- **Priority access** to latest software updates
- **Fast line** to our expert service team
- **Sneak peak** at new features and accessories

[More information](https://www.nippongenetics.eu/en/instrument-registration/)

##### Manual

[Manual | FastGene NanoSpec Photometer | FG-NP01](https://www.nippongenetics.eu/app/uploads/manual-fastgene-nanospec-photometer-fg-np01.pdf)

##### Flyer

[Flyer FastGene NanoSpec Photometer](https://www.nippongenetics.eu/app/uploads/2021/06/fg-np01-nanospec-photometer-flyer.pdf)

 <a id="product-reviews"></a>### Rated **5** out of 5 based on 1 customer rating

1 review for FastGene NanoSpec Spectrophotometer

1. ![](https://secure.gravatar.com/avatar/045ce081e26bebc864f36cdc8b90d3771382900ae4d1710e61b0d5dfab3a693d?s=60&d=mm&r=g)Rated **5** out of 5

     **Franz Leißing, Peter-Bruckmann-Schule Heilbronn**  – 26.03.2025

    Wir nutzen seit 2 Jahren das FastGene® NanoSpec Photometer in der Ausbildung biotechnologischer Assistent\*innen. Die einfache Bedienung, die handliche Bauweise und zuverlässige Messung überzeugt nicht nur uns Lehrkräfte sondern auch unsere Schüler. Auch der Wechsel der Räumlichkeiten ist durch die leichte Bauweise kein Problem. Wir nutzen das Photometer hauptsächlich zu Quantifizierung von DNA (Mikrovolumen) und Proteinen (Küvetten – Bradford-Assay und A280). Die Messungen sind zuverlässig und gut reproduzierbar – auch von ungeübteren Nutzen.

    Translation by NIPPON Genetics EUROPE:
    We have been using the FastGene® NanoSpec photometer for two years in the training of biotechnology assistants. The ease of use, handy design and reliable measurements have not only convinced us as teachers, but also our students. The easy-to-carry design also makes it easy to move the photometer from room to room. We use the photometer mainly to quantify DNA (microvolumes) and proteins (cuvettes – Bradford assay and A280). The measurements are reliable and highly reproducible, even when performed by inexperienced users.



     [Verified User](https://www.nippongenetics.eu/en/authenticity-of-reviews/)



Only logged in customers may leave a review.