# FastGene UF Concentrators

---
url: https://www.nippongenetics.eu/en/products/protein-electrophoresis/ultrafiltration-concentrators/fastgene-uf-concentrators/
language: en
type: product
modified: 2026-04-08T14:09:57+02:00
---

## NEW | Ultrafiltration devices for efficient biomolecule concentration and purification by centrifugal force

## Product Details

- **Stock status**: instock
- **Categories**: Ultrafiltration concentrators

## Attributes

- **Volume**: 0.5 mL, 4 mL, 15 mL
- **Pore size (MWCO)**: 10 kDa, 30 kDa, 100 kDa

- 3 different tube sizes: 0.5 ml, 4 mL, 15 mL
- 3 different pore sizes (MWCO): 10 kDa, 30 kDa, 100 kDa
- Very high sample recovery rate (&gt;90%)
- Minimal protein and nucleic acid adsorption
- Vertical design for fast, clog-free filtration/concentration
- Ultra-low dead volume for maximum yield
- Compatible with standard centrifuge rotors
- Safe, reliable materials

[test a free sample](#section-sample-request)

### Details

- The FastGene® UF Concentrators are designed for rapid concentration, purification, and buffer exchange of proteins, nucleic acids, and other biomolecules.
- They are available in 0.5 mL, 4 mL, and 15 mL sample size tubes (FastGene® UF Concentrators 0.5 mL, FastGene® UF Concentrators 4 mL, FastGene® UF Concentrators 15 mL), with multiple molecular weight cut-offs (MWCO: 10 kDa, 30 kDa, 100 kDa), they ensure excellent sample recovery with minimal binding.
- The vertical dual-membrane design prevents clogging and enables fast flow rates, while the anti-dry lock system protects sensitive samples from over-centrifugation. With low-binding PES membranes, the FastGene® UF Concentrators deliver excellent biocompatibility and reproducibility for research applications.

##### Applications

- Protein and nucleic acid concentration or desalting
- Buffer exchange
- Virus and exosome concentration
- Removal of contaminants from cell lysates
- Clarification of samples prior to chromatography or HPLC

### Products and selection guide

##### The FastGene® UF Concentrators are available as 0,5 mL, 4 mL, and 15 mL sample size tubes.

##### FastGene® UF Concentrators 0.5 mL

**Cat. No.****Volume****MWCO****Colour** **Package size (pc/box)**FG-UFC05-10KD0.5 mL10 kDaTransparent![](https://www.nippongenetics.eu/app/uploads/white.png)96FG-UFC05-30KD0.5 mL30 kDaTransparent![](https://www.nippongenetics.eu/app/uploads/white.png)96FG-UFC05-100KD0.5 mL100 kDaTransparent![](https://www.nippongenetics.eu/app/uploads/white.png)96##### FastGene® UF Concentrators 4 mL

**Cat. No.****Volume****MWCO****Colour** **Package size (pc/box)**FG-UFC4-10KD4 mL10 kDaYellow![](https://www.nippongenetics.eu/app/uploads/yellow.png)40FG-UFC4-30KD4 mL30 kDaGreen![](https://www.nippongenetics.eu/app/uploads/green.png)40FG-UFC4-100KD4 mL100 kDaPink![](https://www.nippongenetics.eu/app/uploads/pink.png)40
##### FastGene® UF Concentrators 15 mL

**Cat. No.****Volume****MWCO****Colour** **Package size (pc/box)**FG-UFC15-10KD15 mL10 kDaYellow![](https://www.nippongenetics.eu/app/uploads/yellow.png)15FG-UFC15-30KD15 mL30 kDaGreen![](https://www.nippongenetics.eu/app/uploads/green.png)15FG-UFC15-100KD15 mL100 kDaPink![](https://www.nippongenetics.eu/app/uploads/pink.png)15
##### Selection guide

Choosing the correct MWCO (Molecular Weight Cut-Off) is essential for optimal recovery and concentration efficiency.
Use smaller MWCO filters for smaller proteins and larger MWCO filters for high-molecular-weight biomolecules such as antibodies, viruses, or exosomes.

**MWCO Filter**
**Membrane****Recommended protein**
**molecular weight range****Centrifugation Time**
**0.5 mL Tubes****Centrifugation Time**
**4 mL Tubes****Centrifugation Time**
**15 mL Tubes**10 kDa~20–60 kDa10–15 min10–30 min10–30 min30 kDa~60–120 kDa&lt; 10 min15–20 min15–20 min100 kDa≥ 150 kDa (large proteins, antibodies, viruses, exosomes)&lt; 10 min20–30 min20–30 min### Specifications

##### Parameter

##### 0.5 mL UF Concentrators

##### 4 mL UF Concentrators

##### 15 mL UF Concentrators

**Centrifuge tube size****1.5/2 mL conical tubes****15 mL conical tubes****50 mL conical tubes****Membrane material**PES (polyethersulfone)PES (polyethersulfone)PES (polyethersulfone)**Tube and cap material**PP (polypropylene)PP (polypropylene)PP (polypropylene)**Filter device material**PC (polycarbonate)
K-resin (Styrene-butadiene Copolymer)PC (polycarbonate)
K-resin (Styrene-butadiene Copolymer)PC (polycarbonate)
K-resin (Styrene-butadiene Copolymer)**Dead volume****≤5 µL****≤20 µL****≤30 µL****Lock volume (min.)****10–20 µL****50–100 µL****~300 µL****Max. RCF****14,000 × _g_****6,000 × _g_**
**(3,000 × _g_ for 100 kDa)****5,000 × _g_**
**(3,000 × _g_ for 100 kDa)****Operating temperature**0–40 °C0–40 °C0–40 °C**pH range**1–141–141–14**Sterilization**Not autoclavable. Sterilize by flushing with 70% ethanol through the
UF ConcentratorNot autoclavable. Sterilize by flushing with 70% ethanol through the
UF ConcentratorNot autoclavable. Sterilize by flushing with 70% ethanol through the
UF Concentrator### Sample request

You would like to convince yourself? Request a free sample.

### FAQ

#### General

##### What are FastGene UF Concentrators used for?

They are used for concentration, desalting, and buffer exchange of biomolecules such as proteins, nucleic acids, and viruses. They can also be used to clarify samples or remove small contaminants

##### What sizes and MWCOs are available?

FastGene® UF Concentrators are offered in three sizes – 0.5 mL, 4 mL, and 15 mL – each in three molecular weight cut-offs (MWCO): 10 kDa, 30 kDa, and 100 kDa.

##### What membrane material is used?

All FastGene® UF Concentrators use a low-binding PES (Polyethersulfone) membrane, ideal for proteins and nucleic acids.

##### What pH range can they handle?

The PES membrane is compatible with pH 1–14, covering most biological and chemical applications.

##### Can I reuse the concentrators?

All FastGene® UF Concentrators are single-use, non-sterile devices. Reuse may reduce performance and risk contamination. Reuse is not recommended.

##### Can they be sterilized?

Do not autoclave. For cleaning or limited sterilization, you may rinse with 70 % ethanol for 30 minutes before use. Always let ethanol evaporate completely.

##### Are the concentrators RNase- or endotoxin-free?

They are not certified RNase-free or endotoxin-free. If required, rinse with 0.1 % DEPC solution at 37 °C for 2 h and then wash thoroughly with ultrapure water.

##### Are the devices chemically compatible with organic solvents or strong reagents?

They are intended for aqueous and biological solutions.
Check the chemical compatibility table (see user manual or list below) before using acids, bases, or solvents.

**Category****Chemical / Reagent****Max. concentration** **Category****Chemical / Reagent****Max. concentration****Acid**Sulfamic acid≤3 %**Organic solvent**BenzeneNot recommendedFormic acid≤5 %AcetoneNot recommendedAcetic acid≤25 %Acetonitrile≤10 %Hydrochloric acid≤1 MTolueneNot recommendedSulfuric acid≤3 %Formaldehyde≤5 %Nitric acid≤10 %DMSO≤5 %Lactic acid≤5 %Ethyl acetateNot recommendedPhosphoric acid≤30 %PyridineNot recommendedTrifluoroacetic acid≤10 %ChloroformNot recommendedTrichloroacetic acid≤10 %Carbon tetrachlorideNot recommended**Base**Sodium hydroxide
(4 mL / 15 mL tubes)≤0.5 MTetrahydrofuranNot recommendedSodium hydroxide
(0.5 mL tubes)≤0.1 M**Other reagent**Phenol&lt; 1 %Ammonium hydroxide≤10 %Glycerol≤70 %**Alcohol**Methanol≤60 %DTT≤0.1 M Ethanol≤70 %DEPC (Diethyl pyrocarbonate)≤0.2 % Isopropanol≤70 %PEG (Polyethylene glycol)≤10 % n-Butanol≤70 %Phosphate buffer (pH 8.2)≤1 M Ammonium sulfateSaturated Imidazole≤500 mM Urea≤8 M β-Mercaptoethanol≤0.01 M Tris buffer (pH 8.2)≤1 M Sodium carbonate≤20 % Guanidine hydrochloride≤6 M#### Usage

##### Can I use them at 4 °C?

Yes. Centrifugation at 4 °C is possible, but viscosity increases at low temperature, so extend the spin time by about 1.5 × times the original duration.

##### How do I collect the concentrated sample?

- 0.5 mL tubes: Use the reverse-spin method – invert the filter into a clean collection tube and centrifuge at 1,000 × _g_ for 1–2 min.
- 4 mL and 15 mL tubes: Collect the concentrate directly with a pipette.

##### How can I improve protein recovery or avoid loss?

- Choose an MWCO about one-third of the target protein’s molecular weight.
- Avoid excessive centrifugal force or long spin times.
- If the sample is viscous or prone to sticking, pre-block the membrane with 10 % glycerol overnight and rinse before use.

##### Can these devices remove detergents or endotoxins?

- Detergents: Only partially; efficiency drops above the CMC value.
- Endotoxins: No, as endotoxins are often &gt;10 kDa and not removed effectively by ultrafiltration.

##### Can FastGene UF Concentrators be used for virus or nanoparticle concentration?

Yes.

- Lentivirus: Use 100 kDa MWCO.
- Adenovirus: Use 50 kDa MWCO.

They are also suitable for nanoparticle and exosome concentration (recommended 50–100 kDa).

##### What centrifuge settings should I use?

- 0.5 mL: Up to 14,000 × _g_
- 4 mL: Up to 6,000 × g (3,000 × _g_ for 100 kDa)
- 15 mL: Up to 5,000 × g (3,000 × _g_ for 100 kDa)

Use swing-bucket or fixed-angle rotors compatible with standard conical tubes. Always balance your samples.

##### Do samples dry out during centrifugation?

No. The FastGene® UF Concentrators feature a dead-volume design that prevents complete drying and protects your sample.

#### Troubleshooting

##### My protein precipitated during concentration — what should I do?

Precipitation can occur when concentrating too quickly or too far. Try:

- Reducing centrifugal force (to 30–50 % of the recommendation).
- Switching to a larger MWCO (e.g., 30 kDa instead of 10 kDa).
- Gently mixing the sample between spins.

##### Why is my target protein missing after centrifugation?

Possible causes:

- The MWCO chosen is too large (target passed through).
- Centrifugal force too high or rotor not calibrated.
- Protein precipitated during spin. Check filtrate and concentrate; if protein is in filtrate, use a smaller MWCO.

### Documents

##### Manual

[Manual | FastGene UF Concentrators | FG-UCF](https://www.nippongenetics.eu/app/uploads/manual-fastgene-uf-concentrators-fg-ufc.pdf)

##### Flyer

[Flyer | FastGene UF Concentrators | FG-UFC](https://www.nippongenetics.eu/app/uploads/flyer-fastgene-uf-concentrators-fg-ucf.pdf)

 <a id="product-reviews"></a>###  Reviews

There are no reviews yet.



Only logged in customers may leave a review.