## Western blot detection kit

## Product Details

- **SKU**: FG-CH01
- **Stock status**: instock
- **Categories**: Protein Electrophoresis, Western Blot

Chemiluminescent substrate based on luminol | **High sensitivity** – Detection of antigens with very low concentrations | **Long signal duration** – Optimal for digital and film-based imaging | **No optimization required** – Easy switch from other brands | Perfect for PDVF and nitrocellulose membranes | Compatible with Western Blotting Markers

- Chemiluminescent substrate based on luminol
- **High sensitivity** – Detection of antigens with very low concentrations
- **Long signal duration** – Optimal for digital and film-based imaging
- **Fast protocol** – 10-30 sec incubation time
- **No optimization required** – Easy switch from other brands
- Perfect for PDVF and nitrocellulose membranes
- Compatible with Western Blotting Markers

### Details

##### FastGene® Western ECL Kit – Chemiluminescent Western Blot Detection

The FastGene® Western ECL Kit is an **e**nhanced **c**hemi**l**uminescent (ECL) substrate based on luminol.
It is used to detect horseradish peroxidase (HRP) – conjugated secondary antibodies.
The high femtogram or low picogram detection of antigen is enabled by FastGene® Western ECL Kit brilliant sensitivity and long signal duration.
This long chemiluminescent signal duration makes it possible to detect signals on both digital and film-based imaging systems without any loss in signal intensity.
Appropriate primary and secondary antibody dilutions are suggested for attaining optimal signal intensity and duration.

##### Workflow using FastGene® Western ECL Kit

![](https://www.nippongenetics.eu/app/uploads/2020/05/fastgenewesterneclkit-workflow-300x130.png)

Mix the luminol solution and peroxide solution in a 1:1 ratio, and thoroughly agitate the chemiluminescent substrate solution well for preparing the 0.1 ml of solution / cm2 of membrane.
Place the membrane with the protein side up and remove the membrane from the chemiluminescent substrate solution. Image the membrane with a digital imager.

### Product comparison

##### Comparison between the FastGene® Western ECL Kit and competitor products

##### A

1000-100 ng BSA were separated in a 4-20% SDS-Page ([FastGene® Precast Gel](https://www.nippongenetics.eu/en/products/protein-electrophoresis/precast-protein-gels/__trashed/)) using a primary antibody 1:5000 alpha-BSA (Invitrogen, A11133, corresponding to 4 µg). All ECL kits were used under the same experimental workflow.

![](https://www.nippongenetics.eu/app/uploads/fg-western-ecl-kit-comparison-5s-exposure.jpg)

![](https://www.nippongenetics.eu/app/uploads/fg-western-ecl-kit-comparison-10s-exposure.jpg)

##### B

An IL-6 fusion protein was detected using a primary antibody against IL-6 from mouse and a secondary anti-mouse peroxide (POD) antibody 2 seconds exposure for the Western Blot. All ECL kits were used under the same experimental workflow.

**![](https://www.nippongenetics.eu/app/uploads/2020/05/fastgene-western-ecl-kit-results.png)**

### Free sample

Request a free sample of the FastGene® Western ECL Kit

### Downloads

##### Manual

[Manual | FastGene Western ECL Kit | FG-CH1](https://www.nippongenetics.eu/app/uploads/fg-ch01-western-ecl-kit-manual.pdf)

##### MSDS

[FG-CH01\_MSDS](https://www.nippongenetics.eu/app/uploads/2020/05/FG-CH01_FastGene-Western-ECL-Kit-Solution-B_MSDS_vers1.pdf)

##### Technical Notes

[Technical Note | FastGene Western ECL Kit | Detection limit for whole cell lysates](https://www.nippongenetics.eu/app/uploads/TCN-FG-CH01-detection-limit-for-whole-cell-lysates.pdf)

[Technical Note | FastGene Western ECL Kit | Detection sensitivity comparison](https://www.nippongenetics.eu/app/uploads/TCN-FG-CH01-detection-sensitivity-comparison.pdf)

 <a id="product-reviews"></a>### Rated **5** out of 5 based on 2 customer ratings

2 reviews for FastGene Western ECL Kit

1. ![](https://secure.gravatar.com/avatar/0d1234f677c879d22bd297de10616fba2bc8de6dcbd6a18a0488ab96a3db5128?s=60&d=mm&r=g)Rated **5** out of 5

     **Daniel Hoff Institut für Pharmazie und Molekulare Biotechnologie Universität Heidelberg**  – 12.03.2026

    Äußerst sensitiv bei einem deutlich besseren Preis verglichen mit ähnlichen Kits anderer Hersteller.
    Translated by NIPPON Genetics EUROPE
    Extremely sensitive, yet significantly better value for money compared to similar kits from other manufacturers.



     [Verified User](https://www.nippongenetics.eu/en/authenticity-of-reviews/)
2. ![](https://secure.gravatar.com/avatar/045ce081e26bebc864f36cdc8b90d3771382900ae4d1710e61b0d5dfab3a693d?s=60&d=mm&r=g)Rated **5** out of 5

     **Katharina Gryksa-Zotz Lehrstuhl für Neurobiologie und Tierphysiologie Universität Regensburg**  – 31.08.2023

    Wir sehen nach 30sec Inkubation bessere Protein Banden als nach 5min Inkubation mit einem vergleichbaren Kit eines anderen Herstellers.

    Translated by NIPPON Genetics EUROPE:
    We see better protein bands after 30 seconds of incubation than after 5 minutes of incubation with a comparable kit from another manufacturer.



     [Verified User](https://www.nippongenetics.eu/en/authenticity-of-reviews/)



Only logged in customers may leave a review.