FastGene qFYR Plus Real-Time PCR System

Real-time fluorescent quantitative PCR system | NEW: 6 channel system

  • Fast detection − Probe & dye-based assays
  • 6 different colour channels – perfect for multiplex qPCR (view channels)
    • Also available with 4+1 channels: 4 different colour channels + 1 additional second FAM/SYBR channel for fast dual mode melt curve analysis (FastGene® qFYR, FG-QPTC01)
  • Standard plate format − 96-well block with gradient function
  • Highest sensitivity
  • Outstanding homogeneity across all wells of a 96-well plate
  • Software included − Easy-to-use and intuitive
  • Integrated Precision Melt Analysis Tool (for probe-based allelic discrimination)
  • Many applications − Gene expression analysis, genotyping, HRM (high resolution melt), pathogen detection, genetic analysis

PRODUCT INQUIRY

Cat. No. FG-QPTC02

Details

Introduction

Highest precision instrument

The FastGene® qFYR is a highest precision instrument for performing quantitative polymerase chain reaction (qPCR) experiments. qPCR is a well-established method for the sensitive detection and quantification of nucleic acids. During a measurement, the target DNA or RNA sequence is amplified, while a cycle-dependent increase of a fluorescent signal is detected in real-time.

The device for multiple applications

The FastGene® qFYR was developed to meet highest laboratory standards and deliver reliable performances for various real-time qPCR applications:

  • Gene expression analysis
  • Absolute and relative quantification
  • Endpoint qualitative analysis
  • Genotyping
  • Gene mutation analysis
  • Pathogen detection
  • GMO detection
  • Protein stability screening
  • miRNA analysis
  • Melting curve analysis

Innovative Technology

High sensitivity optical design

The FastGene® qFYR has a unique, patented optical detection system. It combines a high quality PMT (photomultiplier tube) with a Fresnel lens that has a short focal length. The resulting short distance from detector to sample reduces signal loss and cross-talk between samples, and generally improves signal sensitivity.

Superior thermal cycler performance

The FastGene® qFYR delivers excellent temperature control, temperature precision (± 0.2 °C) and uniformity over the entire 96-well plate. The unique hollowed out thermal block design reduces its overall weight and ensures rapid heating and cooling rates (up to 6 °C per second) for fast qPCR protocols. The system also uses state-of-the-art Peltier components for highest reaction quality and performance stability, providing reliable and consistent qPCR results.


Fast measurement with high performance LED channels

Due to the small distance between the scanning head and the plate, the FastGene® qFYR has an outstanding level of sensitivity and virtually no cross talk between the individual wells.
4 or 6 different colour channels are installed in the scanning head to be able to excite all commonly used qPCR dyes in a single plate scan (8 sec).

The FastGene® qFYR is available in 2 different versions, with:

I) FastGene® qFYR (FG-QPTC01, more information)

The FastGene® qFYR (FG-QPTC01) has 4+1 channels: 4 different colour channels and 1 second FAM channel.
The dual FAM/SYBR channel allows melt curve and high resolution melt experiments to be performed in fast dual mode, halving the measuring time in this channel.

Channel 1: FAM/SYBR Green etc.
Channel 2: VIC/JOE/HEX/TET etc.
Channel 3: ROX/Texas Red etc.
Channel 4: Cy5 etc.
Channel 5: FAM/SYBR Green etc.

II) FastGene® qFYR Plus (FG-QPTC02)

The FastGene® qFYR Plus (FG-QPTC02) has 6 different colour channels.

Channel 1: FAM/SYBR Green etc.
Channel 2: VIC/JOE/HEX/TET etc.
Channel 3: ROX/Texas Red etc.
Channel 4: Cy5 etc.
Channel 5: Cy5.5/Quasar 705/Alexa Fluor 680
Channel 6: ATTO 42

Software | Video tutorials

The powerful user software has it all

The analysis software (FastGene® qFYR Analysis Studio) impresses with its particularly simple and operation. The menu is clearly structured and intuitively arranged. It responds to the needs of the user for different experimental setups, and personalized settings can be easily adjusted. Integrated analysis algorithms allow many steps, such as baseline subtraction or Cq value threshold calculation, to be performed automatically.
Absolute and relative quantification of nucleic acids can also be automated. The software allows you to save predefined analysis settings for auto-exporting run data into a format of choice, including Excel, PDF, txt export format.

  • Clearly structured and user-friendly
  • Intuitive navigation
  • Customizable settings
  • Automatic analysis with integrated algorithms
  • Modules for multiple applications
  • Modern UI design

Video tutorial – Complete webinar | 25:22 min

See how easy it is to (1) install the software, (2) set up the experiments and (3) analyse the data.

Um das YouTube-Video zu sehen, müssen Sie Cookies akzeptieren.

Short video: How to set up your Real-Time PCR experiment in under 3 minutes | 2:51 min

Um das YouTube-Video zu sehen, müssen Sie Cookies akzeptieren.

FasteGene qFYR Real-Time PCR System | Experiment setup | Video thumbnail
Short video: How to analyse and export your real-time data in under 2 minutes | 1:29 min

Um das YouTube-Video zu sehen, müssen Sie Cookies akzeptieren.

FasteGene qFYR Real-Time PCR System | Data analysis and export | Video thumbnail

Application data

Generate high quality data

The combination of innovative optics and a high-precision thermal block ensure ideal amplification conditions. This makes the FastGene® qFYR ideal for various quantitative real-time PCR applications.

Outstanding homogeneity

FastGene® qFYR shows great homogeneity across all wells of a 96-well plate.

Figure 1: Amplification of 1 ng plasmid DNA in all 96 wells of a PCR plate. The mean Cq value at a cycle number of 13.89 +/- 0.055 was determined automatically, illustrating highly homogenous amplification results obtained by the FastGene® qFYR.

Powerful multiplexing

FastGene® qFYR Plus can discriminate up to 6 different targets in a single reaction well, helping you save time, conserve reagents, and reduce samples usage without sacrificing precision.

Figure 2: Multiplex amplification of six mammalian housekeeping genes (GAPDH, B2M, ACTG1, PGK1, HPRT1, and ACTB ). Each gene was detected using a different fluorescent probe: FAM – GAPDH, HEX – B2M, TexasRed – ACTG1, Cy5.5 – PGK1, ATTO425 – HPRT1, Cy5 – ACTB.

Accurate quantification

The broad dynamic range of the FastGene® qFYR ensures a reliable and accurate quantification.

Figure 3: The amplification plot shows the log of change in normalized reporter fluorescence against the cycle number. The amplification took place from plasmid DNA with AMP specific primers in a 10-fold dilution series ranging from 1 ng to 1×10-6 ng plasmid DNA. The generated standard curve shows 100 % efficiency.

1.3-fold target discrimination

With the FastGene® qFYR, smaller concentration differences can be distinguished with high accuracy, underlining the high sensitivity of the device.

Figure 4: The amplification of plasmid DNA was carried out using AMP-specific primers with a 2-fold dilution series starting at 0.1 ng with additional dilutions of 1:1.3, 1:1.4, 1:1.5 and 1:1.6. Concentration differences can be detected up to 1:1.3-fold dilution.

Melt curve analysis

The Precision Melt Analysis Tool is a powerful method for probe-based allelic discrimination. This function is already included in the FastGene® qFYR analysis software and does not need to purchased additionally.

Figure 5: The difference plot of the high-resolution melting curve allows the discrimination between SNPs extracted from blood samples for brown eyes and two variants of blue eyes.

Gradient qPCR for optimal annealing

The thermal gradient function of the FastGene® qFYR can be used to determine the optimal annealing temperature of a specific target.

Figure 6: Plasmid amplification with IC green dye was carried out in a 10-fold dilution series from 1 ng to 1×10-6 ng. This example of a thermal gradient experiment with 55 °C and 68 °C shows 55 °C to be the optimal annealing temperature with a 100% efficiency.

Specifications

Thermal cycler
FastGene® qFYR Plus (FG-QPTC02)
6 channel system
FastGene® qFYR (FG-QPTC01)
4+1 channel system
Block capacity 96 96
Sample volume 5–100 µL 5–100 µL
Heating and cooling method Peltier (6 temperature control modules) Peltier (6 temperature control modules)
Temperature control technology Hollow-out module combined with edge temperature compensation technology Hollow-out module combined with edge temperature compensation technology
The maximum heating and cooling rate of the block 6.0 °C/s 6.0 °C/s
The average heating and cooling rate of the sample 4.0 °C/s 4.0 °C/s
Temperature range 4.0 °C/s 4.0 °C/s
Temperature accuracy ± 0.2 °C ± 0.2 °C
Temperature uniformity ± 0.2 °C ± 0.2 °C
Temperature setting range 4–100 °C 4–100 °C
Heated lid Electronic automatic lid Electronic automatic lid
Gradient zones 12 columns 12 columns
Temperature gradient temperature range 1–40 °C 1–36 °C
Linear dynamic range 10 orders of magnitude: 1-1010 copies 10 orders of magnitude: 1-1010 copies
Software name FastGene®qFYR Analysis Studio FastGene®qFYR Analysis Studio
Optical detection
FastGene® qFYR Plus (FG-QPTC02)
6 channel system
FastGene® qFYR (FG-QPTC01)
4+1 channel system
Excitation light source 6 single-color high-efficiency LEDs
(maintenance-free, working life >100,000 hours)
4 single-color high-efficiency LEDs
(maintenance-free, working life >100,000 hours)
Detector device Highly sensitive PMT (photo multiplier tube) with Frensel lens Highly sensitive PMT (photo multiplier tube) with Frensel lens
Scanning principle Time-resolved real-time scan Time-resolved real-time scan
Fluorescent channel number 6 channels 4 channels (2x FAM)
Application to fluorescent
  • Channel 1: FAM/SYBR Green etc.
  • Channel 2: VIC/JOE/HEX/TET etc.
  • Channel 3: ROX/Texas Red etc.
  • Channel 4: Cy5 etc.
  • Channel 5: Cy5.5/Quasar 705/Alexa Fluor 680
  • Channel 6: ATTO 425
  • Channel 1: FAM/SYBR Green etc.
  • Channel 2: VIC/JOE/HEX/TET etc.
  • Channel 3: ROX/Texas Red etc.
  • Channel 4: Cy5 etc.
  • Channel 5: FAM/SYBR Green etc.
Dye compatibility
  • FAM/SYBR Green
  • VIC/HEX/TET/JOE
  • ROX/Texas Red, Mustang Purple
  • Cy5/LIZ
  • Cy5.5/Quasar 705/Alexa Fluor 680
  • ATTO 425
  • FAM/SYBR Green
  • VIC/HEX/TET/JOE
  • ROX/Texas Red, Mustang Purple
  • Cy5/LIZ
Detector position Top of the block Top of the block
Detection sensitivity 1 copy of the target sequence 1 copy of the target sequence
System sensitivity Distinguishable 1.33-fold copy number difference in singleplex reactions Distinguishable 1.33-fold copy number difference in singleplex reactions
Detection time
  • Standard mode (full channel): 8.5 seconds/96-well plate
  • Standard mode (full channel): 8.5 seconds/96-well plate
  • Fast mode (dual FAM): 4 seconds/96-well plate
Exitation/detection range
  • Excitation range: 415–685 nm;
  • Scope of test: 455–745 nm
  • Excitation range: 455–650 nm;
  • Scope of test: 510–715 nm
Physical specifications
FastGene® qFYR Plus (FG-QPTC02)
6 channel system
FastGene® qFYR (FG-QPTC01)
4+1 channel system
Instrument specifications
  • Dimensions: 35 cm x 52 cm x 37 cm (length x wide x height)
  • Weight: 25 kg
  • Dimensions: 35 cm x 52 cm x 37 cm (length x wide x height)
  • Weight: 25 kg
Environmental conditions
  • Temperature: 10–30 °C
  • Humidity: ≤85 % RH no condensation
  • Atmosheric pressure: 85.0 kPa ~ 106.0 kPa
  • Altitude: < 2000 m
  • Temperature: 10–30 °C
  • Humidity: ≤85 % RH no condensation
  • Atmosheric pressure: 85.0 kPa ~ 106.0 kPa
  • Altitude: < 2000 m
Power supply specification
  • Power supply voltage: AC 100–240 V
  • Frequency: 50 Hz
  • Power: 750 W
  • Power supply voltage: AC 100–240 V
  • Frequency: 50 Hz
  • Power: 750 W
Data communication interface USB ports USB ports

 

Compatibility & Consumables

Get the right consumables for FastGene® qFYR

The FastGene® qFYR is compatible with low-profile (0.1 mL) PCR tubes/8-well PCR tube strips with transparent, flat tops as well as non-skirted or half-skirted low profile 96 well PCR reaction plates (See product category: PCR Plastic (link)):

  • Single tubes: Low-profile (0.1 mL) clear/white PCR thin-walled single tube, flat-topped transparent optical tube cover, e.g.:
  • 8-well strips: Low-profile (0.1 mL) clear/white PCR thin-walled 8-tube, flat-top transparent optical tube cover, e.g.:
    • 8-well PCR Tube Strips 0.1 mL with flat cap strips (FG-017FC)
    • 8-well PCR Tube Strips 0.1 mL with flat caps (FG-018WF)
    • 8-well White PCR Tube Strips 0.1 mL + optical Flat Cap Strips (FG-019FC)
  • 96-well plates: Low-profile (0.1 mL) clear/white PCR thin-walled 96- well plate with no hemline or hemline, e.g.:
    • FastGene® White 96-well PCR Plate 0.1 mL, semi-skirted (FG-2102)
    • FastGene® 96-well PCR Plate 0.1 mL, non-skirted (FG-170350)
    • FastGene® 96-well Fast PCR Plate 0.1 mL (FG-03890-50)

! It is not compatibel with high-profile (0.2 mL) PCR reaction tube and convex tube covers !

Info: If the sample tubes are just a few, use 8-well tubes for support on both sides, or use empty single tubes in the four corners to prevent uneven force on the plate slot.

Dye compatibility

Our FastGene® IC Green and Probe Mixes are the ideal reagents for the FastGene® qFYR.
Find the right dye mix for your application: PCR reagents and enzymes – Quantitative PCR (link).

F1: FAM/SYBR Green
F2: VIC/HEX/TET/JOE, JUN
F3: ROX/Texas Red, Mustang Purple
F4: Cy5/LIZ
F5: Cy5.5/Quasar 705/Alexa Fluor 680 (FastGene® qFYR Plus only)
F6: ATTO 425 (FastGene® qFYR Plus only)

Computer configuration requirements

The computer installed with the FastGene® qFYR Analysis Studio must have the following configuration:
Processor: Intel or AMD dual-core CPU,2.8GHz
Memory: 4 GB
Hard disk: 500 GB
Network card: 10 M/100M adaptive network card (optional)
Display resolution: 1440×900 or higher
Operating system: Windows 10 or above & Office Word/Excel 2007 or above.

For furher details, please refer to the user manual, section ‘Installation Requirements’.

Downloads

Manual

Manual – FastGene qFYR Real-Time PCR System (FG-QPTC01, FG-QPTC02)

Brochure

Brochure – FastGene qFYR Real-Time PCR System (FG-QPTC01. FG-QPTC02)

Whitepaper

Whitepaper | How a powerful multiplex PCR System simplifies laboratory workflows | FastGene qFYR (Plus)

Product inquiry


Reviews

There are no reviews yet.

Only logged in customers may leave a review.